top of page

TAURO Inverter 

DESIGNED TO PERFORM

The three-phase Fronius Tauro in the 50 kW power class promises maximum performance, even under the harshest conditions. With its smart hardware design, it not only contributes to BOS cost optimization, but also offers unprecedented flexibility in system design. The Fronius Tauro can be used to implement sophisticated roofs in both centralised (P variant) and decentralised system designs (D variant). Simplest installation and the fastest service on the market also guarantee maximum safety.

Fronius Tauro. Designed to perform.

tauro.png
arrow&v

NOTES FOR TECHNICAL DATA

1) According to IEC 62109-1  

2) Unrestricted voltage range

3) At 580Vdc / 800Vdc / 930Vdc

4) Direct in the sun is possible

5) At an ambient temperature of 50°C

6) AC-, DC -Overvaltage protection; Typ 1+2: Iimp 5kA

7) An Ethernet star-configuration is used for communication with multiple inverters. Each individual inverter communicates independently with the network/Internet via its integrated data logger

8) Find more certifications at www.fronius.com/tauro-cert 

9) At 230 V actual mains voltage; design recommendation (Umpp min): 600V

 

* Isc pv = Isc max ≥ Isc (STC) x 1,25 according to e.g..: IEC 60364-7-712, NEC 2020, AS/NZS 5033:2021.

FRONIUS TAURO ECO 50-3-D DETAILS

TECHNICAL DATA

INPUT DATA

INPUT DATA

Number of MPP trackers

1

Max. input current (Idc max)

87,5 A

DC input voltage range (Udc min - Udc max)

580 - 1000 V

Feed-in start voltage (Udc start)

650 V

MPP voltage range (Umpp min - Umpp max)

580 - 930 V

Max. PV generator power (Pdc max

75 kWpeak

Max. input current PV1 (Idc max, PV1)

75 A

Max. input current PV2 (Idc max, PV2)

75 A

Max. short-circuit current PV1 (Isc max, PV1)*

125 A

Max. short-circuit current PV2 (Isc max, PV2)*

125 A

60 kWpeak

Max. power PV system PV1 (Pdc max,PV1)

60 kWpeak

Max. power PV system PV2 (Pdc max, PV2)

Max. AC fuse size rating

355 A

Max. short-circuit current inverter (Isc max, inverter)

178 A

20 A

Max. short-circuit current string (Isc max, string)

14,5 A

Max. input current string (Idc max, String)

7

Number of DC connections PV1

7

Number of DC connections PV2

30 A

Max. short-circuit current string (Isc max, string) - 30 A Option

22 A

Max. input current string (Idc max, String) - 30 A Option

4

Number of DC connections PV1 - 30 A Option

5

Number of DC connections PV2 - 30 A Option

OUTPUT DATA

AC nominal output (Pac,r)

50 kW

Max. output power (Pac max)

50 kVA

AC output current (Iac nom)

75,8A at 220Vac , 72,5A at 230Vac

Grid connection (Uac,r)

3~ NPE 380/220 , 3~ NPE 400/230 V

AC voltage range (Umin - Umax)

180 - 270 V

Frequency (fr)

50 / 60 Hz

Frequency range (fmin - fmax)

45 - 65 Hz

Total harmonic distortion

<3% @Pnom (230/400VAC 50Hz)

Power factor (cos φac,r)

0 - 1 ind,/cap,

Max. DC fuse size rating

20 A

GENERAL DATA

Width

1109 mm

Height

755 mm

Depth

346 mm

Weight

74 kg

Weight incl. packaging

92 kg

Degree of protection

IP 65

Protection class

1

Overvoltage category (DC / AC) 1)

2 / 3

Night-time consumption

15W

Installation

Indoor and outdoor 4)

Ambient temperature range

-40°C - +65°C (optional AC-disconnect: from - 30 to + 65 °C)

Permitted humidity

0 - 100 %

Max. altitude 2)

4000

Certificates and compliance with standards

VDE-AR-N 4105, VDE-AR-N 4110, IEC 62109-1/-2, IEC 62116, IEC 61727 R25, AS/NZS 4777, CEI 0-16, CEI 0-21, EN 50549-1/-2, VDE 0126-1-1 8)

Inverter topology

Transformerless

Cooling

Active cooling technology and double wall system

Sound emissions

68,5 dB(A)

Interference emission class

B

EFFICIENCY

Max. efficiency (PV - grid)

98,5 %

European efficiency (ηEU)

98,2 / 97,7 / 97,3 (580Vdc / 800Vdc / 930Vdc)

η at 5% Pac,r 3)

95,38 / 90,94 / 89,10 (580Vdc / 800Vdc / 930Vdc)

η at 10% Pac,r 3)

97,31 / 95,45 / 93,68 (580Vdc / 800Vdc / 930Vdc)

η at 20% Pac,r 3)

98,18 / 97,41 / 96,83 (580Vdc / 800Vdc / 930Vdc)

η at 25% Pac,r 3)

98,35 / 97,76 / 97,33 (580Vdc / 800Vdc / 930Vdc)

η at 30% Pac,r 3)

98,40 / 97,92 / 97,60 (580Vdc / 800Vdc / 930Vdc)

η at 50% Pac,r 3)

98,51 / 98,22 / 97,99 (580Vdc / 800Vdc / 930Vdc)

η at 75% Pac,r 3)

98,40 / 98,23 / 98,05 (580Vdc / 800Vdc / 930Vdc)

η at 100% Pac,r 3)

98,25 / 98,11 / 98,01 (580Vdc / 800Vdc / 930Vdc)

MPP adaptation efficiency